로그인 회원가입
icon_bulk_order대량 주문 Acrobiosystems for English
0
장바구니가 비어 있습니다
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0-9
Your Position: > Buffer > > LY-14

Lysis Buffer for SARS-CoV-2 Antigen Test Development

  • Description

    The lysis buffer is for rapid extraction of virus antigen from virus cultures, swab or saliva specimens, and other compatible samples. This product can improve virus lysis efficiency and accuracy of antigen detection. It is suitable for various diagnostic technology platform, i.e., colloidal gold immunoassay, immunofluorescence chromatography, chemiluminescence. This product is not suitable for ELISA (Enzyme-Linked Immunosorbent Assay).

  • Attention

    Samples should be sent to the laboratory and treated with lysis buffer as soon as possible after collection. If long-distance transportation is needed, dry ice or other methods of refrigeration are recommended for preservation of the samples.

    If the processed sample cannot be immediately tested, please store the sample at 2 to 8 °C for 2 days; -20°C for 3 months; or -70°C for long term storage. Please avoid repeated freeze-thaw cycles.

  • Procedure for assay

    1. Treatment of swab samples
    1) Place the extraction tube on the workbench and add the lysis buffer to the extraction tube (150μL to 250μL for each sample).
    2) Insert the swab into the extraction tube which contains extraction reagent. Roll the swab for a minimum of 5 times while pressing its head against the bottom and side of the extraction tube to release the antigen. Keep the swab in the tube for 1 min.
    3) To drain the liquid from the swab as much as possible, remove the swab while squeezing the wall of the tube. The liquid extraction will be used as test sample [Dispose the swab as per biohazard waste disposal guidelines].
    4) Perform antigen detection test for the treated swab specimens.
    2. Treatment of virus cultures
    1) Add lysis buffer to the inactivated virus culture.
    2) To fully lyse the virus, incubate the virus culture in lysis buffer for at least 5 mins.
    3) Perform antigen detection test for the treated virus culture.

  • Shipping and Storage

    The product is shipped at room temperature. Upon receipt, please store the buffer at room temperature away from light. Before use, make sure the buffer is at room temperature.

    This product is stable for up to 1 year from the date of receipt at room temperature (4°C~30°C).

코멘트 (0)


재고상품 출발날짜: 영업일 기준 4일

가격(KRW) : 15,000

가격(KRW) : 150,000

가격(KRW) : 750,000

가격(KRW) : 1,350,000

보급 및 전시



Datasheet & Documentation

DMF 신청
DMF (Drug Master File)

관련 제품

신제품

문의와 컨텐츠

This web search service is supported by Google Inc.

totop