Human CXCL9/MIG ELISA Kit

Customer Reviews
Cat. No. / Size
Price
Qty
CEA-C220-96tests
$590.00
ETA of in-stock products:2 business days

Product Details

  • Product Overview

    Human CXCL9/MIG ELISA Kit is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant human CXCL9/MIG that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ELISA Kit provides several benefits:

    1. Standards to calibrate with NIBSC/WHO standards for comparable results.
    2. Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
    3. High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
    4. Simplified and straightforward protocols and ready-to-use reagents to save assay time.

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    CXCL9/MIG
    Format
    96-wells plate breakable into 12 x 8 wells strips
    Reactivity
    Human
    Sensitivity
    20 pg/mL
    Assay Time
    2.75 hr
    Sample volume
    50 μL
    Range
    31.25 pg/mL-2000 pg/mL
    Sample Type
    For the quantitative determination of human CXCL9/MIG in serum, plasma and cell supernatant.

    Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.

  • Application

    The kit is developed for quantitative detection of natural and recombinant human CXCL9/MIG in serum, plasma and cell culture supernatants.

    It is for research use only.

  • Workflow

    CXCL9/MIG Workflow

  • Storage

    Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    CEA220-C01
    Pre-coated Anti-CXCL9/MIG Antibody Microplate
    1 plate
    CEA220-C02
    Human CXCL9/MIG Standard
    5 μg/mL×2
    CEA220-C03
    Biotin-Anti-CXCL9/MIG Antibody Con. Solution
    100 μL
    CEA220-C04
    Biotin-Antibody Dilution Buffer
    8 mL
    CEA220-C05
    Streptavidin-HRP Con. Solution
    500 μL
    CEA220-C06
    Streptavidin-HRP Dilution Buffer
    15 mL
    CEA220-C07
    20× Washing Buffer
    50 mL
    CEA220-C08
    Sample Dilution Buffer
    15 mL×2
    CEA220-C09
    Substrate Solution
    12 mL
    CEA220-C10
    Stop Solution
    6 mL
  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data 

    Please refer to DS document for the assay protocol.

     CXCL9/MIG TYPICAL DATA

    For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of CXCL9/MIG is less than 20 pg/mL.

Validation
  • Sample Values

    Twenty-four healthy serum samples were evaluated for the concentrations of human CXCL9/MIG in assay. The detection human CXCL9/MIG rate of the samples was 100%, the range was 74.905 - 868.877 pg/mL, and the mean detectable value was 256.794 pg/mL.

     CXCL9/MIG SAMPLE VALUES
  • Dilution Linearity

    Three Serum samples with high concentrations of native CXCL9/MIG were serially diluted with dilution buffer to produce samples with values within the dynamic range of the assay and then assayed. The average recovery of CXCL9/MIG for serum samples is 109.33%.

     CXCL9/MIG DILUTION LINEARITY
  • Intra-Assay Statistics

    Eight replicates of each of 3 samples containing different CXCL9/MIG concentrations were tested in one assay. Acceptable criteria: CV<10%.

     CXCL9/MIG INTRA-ASSAY STATISTICS
  • Inter-Assay Statistics

    Three samples containing different concentrations of CXCL9/MIG were tested in independent assays. Acceptable criteria: CV<15%.

     CXCL9/MIG INTER-ASSAY STATISTICS

Customer Reviews
Writing Reviews

Recent Advances

 
Contact Us
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews
Contact Us

전화
글로벌: +1 800-810-0816 (무료)
아시아태평양: +86 400-682-2521

주소 서울특별시 송파구 법원로11길 11, 제3층 제비-314,315호