Reporter Cell Line Validation Service

When establishing reporter gene assays, signal response may vary between various reporter cell lines. Researchers spent major efforts to pick the right reporter cell line to optimize the signal. Throughout this process, validated positive samples within the existing reporter cell lines are kept as the reference for future repurchase or switching.

To assist and shorten the decision time when you are choosing ACROBiosystems reporter cell line, we offer a free Reporter Cell Line Validation Service.

To take advantage of this service, researchers only need to provide previously validated positive samples to ACROBiosystems’s US lab to perform the validation using the desired reporter cell line to deliver EC50 and antibody neutralization data. This validation enables a timely assessment of the cell line’s suitability in real application scenarios, reduce uncertainty associated with method transition, and improve the stability and efficiency of subsequent experiments.

Service Value

Zero-cost validation service to ensure worry-free switch by verifying signal response in ACROBiosystems’s reporter cell lines using validated positive samples before purchase.

Evaluate the compatibility between the reporter cell line and your existing assay system before purchase

Build confidence in cell line performance during the product selection stage.

Lower procurement risk through decisions made from validation results.

Service Period

Service stage Timeline
Cell Line Passage 1 week
Validation assay & report 1 week

Service Inquiry

Neutralizing Activity Validation

Wondering if the ACROBiosystems’s reporter cell line can meet your specific assay requirements?

Complete the request form below to discuss your project needs with our technical specialists, we’ll get back to you with a proposal and timeline within 1 business day.

Submit service inquiry

Notes:
Free service when (1) validation is successful (2) purchase ACROBiosystems’s reporter cell line tested
If validation failed, this service is free of charge.
If the validation is successful without purchasing ACROBiosystems’s reporter cell lines, the service fee will be charged.

Case Study

Agonistic Activity Validation

Agonistic Activity Validation

TSHR (Luc) HEK293 Reporter Cell (Cat. No. CHEK-ATF187)The anti-human TSHR agonistic antibody demonstrated a clear dose-dependent activation response in the ACRO TSHR reporter cell line. The EC50 of anti-human TSHR agonistic antibody was approximately 0.1767 μg/mL with the max induction fold 30.53, indicating potent agonistic activity. The isotype control showed negligible response, confirming the high specificity and low background of the reporter system. These results demonstrate that the TSHR reporter cell line is highly sensitive and suitable for functional evaluation of agonistic antibodies targeting GPCR pathways.

Agonistic Activity Validation

Human GLP-1R (Luc) HEK293 Reporter Cell (Cat. No. CHEK-ATF096)
Bioactivity analysis of human GLP-1R agonist (FOLD). This reporter cell was incubated with serial dilutions of Tirzepatide (a dual GLP-1R and GIPR agonist). The max induction fold was approximately 334.81.

Neutralizing Activity Validation

Neutralizing Activity Validation

Human DR3 (TL1A receptor) (Luc) Jurkat Reporter Cell (Cat. No. SCJUR-STF178) Inhibition of human TL1A protein-induced reporter activity.This reporter cell was incubated with serial dilutions of antibodies in the presence of human TL1A protein (Cat. No. TLA-H5243) with a final concentration of 0.02 μg/mL. The EC50 of anti-human TL1A neutralizing antibody is approximately 0.018 μg/mL.

Neutralizing Activity Validation

Human TACI (Luc) HEK293 Reporter Cell (Cat. No. CHEK-ATF197) Inhibition of human BAFF protein-induced reporter activity by human BAFF and APRIL dual inhibitor.The Human TACI (Luc) HEK293 Reporter Cell was incubated with serial dilutions of inhibitors in the presence of human BAFF protein (Cat. No. BAF-H52D4) with a final concentration of 0.3 μg/mL. The EC50 of Telitacicept is approximately 0.1883 μg/mL. The EC50 of Atacicept is approximately 0.1956 μg/mL.

Platform Introduction

Neutralizing Activity Validation

Neutralizing Activity Validation

Neutralizing Activity Validation

  • Background
  • Service Value
  • Service Period
  • Service Inquiry
  • Case Study
  • Platform Introduction
Contact Us

전화
글로벌: +1 800-810-0816 (무료)
아시아태평양: +86 400-682-2521

주소 서울특별시 송파구 법원로11길 11, 제3층 제비-314,315호