Human IL-8 ELISA Kit, PRO

사용자 리뷰
제품 번호/규격
가격
수량
CEA-C004-96tests
$565.00
CEA-C004-960tests (96tests X 10)
$5090.00
CEA-C004-2880tests (96tests X 30)
$13570.00
ETA of in-stock products:2 business days
총 항목 수 제품 금액$ 0

제품 세부정보

  • Product Overview

    Human IL-8 ELISA Kit, PRO is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant human IL-8 that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ELISA Kit provides several benefits:

    1. Standards to calibrate with NIBSC/WHO standards for comparable results.
    2. Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
    3. High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
    4. Simplified and straightforward protocols and ready-to-use reagents to save assay time.

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    IL-8
    Format
    96-wells plate breakable into 12 x 8 wells strips
    Reactivity
    Human
    Sensitivity
    3.0 pg/mL
    Assay Time
    1.75 hr
    Sample volume
    50 μL
    Range
    6.25 pg/mL-400 pg/mL
    Sample Type
    Cell Culture Supernatants, Plasma, Serum.
    NIBSC Code
    89/520

    Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.

  • Application

    The kit is developed for quantitative detection of natural and recombinant human IL-8 in serum, plasma and cell culture supernatants.

    It is for research use only.

  • Workflow

    IL-8 Workflow

  • Storage

    Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    CEA004-C01
    Pre-coated Anti-IL-8 Antibody Microplate
    1 plate
    CEA004-C02
    IL-8 Calibrator
    20 μg×2
    CEA004-C03
    Biotin-Anti-IL-8 Antibody Concentrated Solution
    100 μL
    CEA004-C04
    Biotin Antibody Dilution Buffer
    8 mL
    CEA004-C05
    IL-8 Streptavidin-HRP Concentrated Solution
    0.5 mL
    CEA004-C06
    Streptavidin-HRP Dilution Buffer
    15 mL
    CEA004-C07
    20×Washing Buffer
    50 mL
    CEA004-C08
    Sample Dilution Buffer
    15 mL×2
    CEA004-C09
    Substrate Solution
    12 mL
    CEA004-C10
    Stop Solution
    6 mL
  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

고객님도 확인한 상품

데이터 표시

  • Typical Data 

    Please refer to DS document for the assay protocol.

     IL-8 TYPICAL DATA

    For each experiment, each ELISA plate needs to set the standard curve. The minimum detectable concentration of CEA-C004 is less than 3.0 pg/mL.

Validation
  • Sample Values

    Serum Sample: Two hundred and forty healthy serum samples were evaluated for the concentrations of human IL-8 in assay.

     IL-8 SAMPLE VALUES
  • Dilution Linearity

    Three human serum samples with high concentrations of IL-8 were diluted 1:2, 1:4, 1:8, 1:16, 1:32 with Dilution Buffer to produce samples with values within the dynamic range and then assayed. On average, 103.12% of IL-8 was detected from serum samples.

     IL-8 DILUTION LINEARITY
  • Intra-Assay Statistics

    Ten replicates of each of five samples containing different IL-8 concentrations were tested in one assay , Intra-Assay Precision CV<10%.

     IL-8 INTRA-ASSAY STATISTICS
  • Inter-Assay Statistics

    Five samples containing different concentrations of IL-8 were tested in three independent assays , Inter-Assay Precision CV<15%.

     IL-8 INTER-ASSAY STATISTICS
  • Recovery

    Recombinant IL-8 was spiked into five human serum samples, and then analyzed. On average, 97.54% of IL-8 was recovered from serum samples.

     IL-8 RECOVERY

    Recombinant IL-8 was spiked into cell supernatant sample, and then analyzed. On average, 98.87% of IL-8 was recovered from serum samples.

     IL-8 RECOVERY
  • Interference effect

    Bilirubin (simulated jaundice) concentration should be less than 20mg/dL, hemoglobin (simulated hemolysis) concentration should not be higher than 3500mg/dL, triglyceride (simulated lipemia) concentration may not be higher than 2.0g/L, Heparin concentration should be less than 40U/mL, EDTA concentration should be less than 4mg/mL, and Sodium citrate concentration may not be higher than 40mg/mL, it does not affect the detection result.

     IL-8 INTERFERENCE EFFECT

사용자 리뷰
댓글 남기기

프론티어 진행

 
의약품 개발 진행
  • 영어 이름:

    Interleukin-8

  • 카테고리:

  • 상장 의약품 수:

    1 상세

  • 임상 의약품 수:

    6 상세

  • 최고 개발 단계:

    Approved

연락하기
신약 후보물질 라이선싱
더 많이 알아보기
  • 기본 제품 정보
  • 제품 세부정보
  • 고객님도 확인한 상품
  • 데이터 표시
  • 사용자 리뷰
문의하기

전화
글로벌: +1 800-810-0816 (무료)
아시아태평양: +86 400-682-2521

주소 서울특별시 송파구 법원로11길 11, 제3층 제비-314,315호