Human MCP-1 / CCL2 ELISA Kit

사용자 리뷰
제품 번호/규격
가격
수량
CEA-B036-96tests
$565.00
CEA-B036-480tests (96tests X 5)
$2825.00
ETA of in-stock products:2 business days
총 항목 수 제품 금액$ 0

제품 세부정보

  • Product Overview

    Human MCP-1/CCL2 ELISA Kit is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant human CCL2 that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ELISA Kit provides several benefits:

    1. Standards to calibrate with NIBSC/WHO standards for comparable results.
    2. Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
    3. High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
    4. Simplified and straightforward protocols and ready-to-use reagents to save assay time.

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    MCP-1
    Format
    96-wells plate breakable into 12 x 8 wells strips
    Reactivity
    Human
    Sensitivity
    2 pg/mL
    Assay Time
    3 hr
    Sample volume
    50 μL
    Range
    4.688 pg/mL-300 pg/mL
    Sample Type
    Cell Culture Supernatants, Plasma, Serum.
    NIBSC Code
    92/794

    Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.

  • Application

    The kit is developed for quantitative detection of natural and recombinant human CCL2 in serum, plasma and cell culture supernatants.

    It is for research use only.

  • Workflow

    CCL2 Workflow

  • Storage

    Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    CEA036-C01
    Pre-coated Anti-MCP-1 Antibody Microplate
    1 plate
    CEA036-C02
    Human MCP-1 Standard
    150 ng×2
    CEA036-C03
    Biotin-Anti-MCP-1 Antibody Con. Solution
    150 μL
    CEA036-C04
    Biotin-Antibody Dilution Buffer
    8 mL
    CEA036-C05
    Streptavidin-HRP Con. Solution
    500 μL
    CEA036-C06
    Streptavidin-HRP Dilution Buffer
    15 mL
    CEA036-C07
    20×Washing Buffer
    50 mL
    CEA036-C08
    Sample Dilution Buffer
    15 mL×2
    CEA036-C09
    Substrate Solution
    12 mL
    CEA036-C10
    Stop Solution
    6 mL
  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

고객님도 확인한 상품

데이터 표시

  • Typical Data 

    Please refer to DS document for the assay protocol.

     CCL2 TYPICAL DATA

    For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of MCP-1 is less than 2 pg/mL.

Validation
  • Sample Values

    Serum Sample: Eighteen healthy serum samples were evaluated for the concentrations of human MCP-1/CCL2 in assay. Sample value range is 20000 – 60000 pg/mL.

     CCL2 SAMPLE VALUES
  • Recovery

    Recombinant MCP-1 was spiked into three human serum samples, and then analyzed. The average recovery of MCP-1 for serum samples is 108%.

     CCL2 RECOVERY

사용자 리뷰
댓글 남기기

프론티어 진행

 
의약품 개발 진행
  • 영어 이름:

    C-C motif chemokine 2

  • 카테고리:

  • 상장 의약품 수:

    1 상세

  • 임상 의약품 수:

    3 상세

  • 최고 개발 단계:

    Approved

연락하기
신약 후보물질 라이선싱
더 많이 알아보기
  • 기본 제품 정보
  • 제품 세부정보
  • 고객님도 확인한 상품
  • 데이터 표시
  • 사용자 리뷰
문의하기

전화
글로벌: +1 800-810-0816 (무료)
아시아태평양: +86 400-682-2521

주소 서울특별시 송파구 법원로11길 11, 제3층 제비-314,315호