Human ANGPTL3 ELISA Kit, PRO

Customer Reviews
Cat. No. / Size
Price
Qty
CEA-B089-96tests
$515.00
CEA-B089-480tests (96tests X 5)
$2310.00
ETA of in-stock products:2 business days

Product Details

  • Product Overview

    Human ANGPTL3 ELISA Kit, PRO is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant human ANGPTL3 that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ELISA Kit provides several benefits:

    1. Standards to calibrate with NIBSC/WHO standards for comparable results.
    2. Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
    3. High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
    4. Simplified and straightforward protocols and ready-to-use reagents to save assay time.

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    ANGPTL3
    Format
    96-wells plate breakable into 12 x 8 wells strips
    Reactivity
    Human
    Sensitivity
    0.156 ng/mL
    Assay Time
    2.75 hr
    Sample volume
    50 μL
    Range
    0.156 ng/mL-10 ng/mL
    Sample Type
    Cell Culture Supernatants, Plasma, Serum.

    Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.

  • Application

    The kit is developed for quantitative detection of natural and recombinant human ANGPTL3 in serum, plasma and cell culture supernatants.

    It is for research use only.

  • Workflow

    ANGPTL3 Workflow

  • Storage

    Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    CEA089-B01
    Pre-coated Anti-ANGPTL3 Antibody Microplate
    1 plate
    CEA089-B02
    Human ANGPTL3 Standard
    40 μg×2
    CEA089-B03
    Biotin-Anti-ANGPTL3 Antibody Con. Solution
    100 μL
    CEA089-B04
    Biotin-Antibody Dilution Buffer
    8 mL
    CEA089-B05
    Streptavidin-HRP Con. Solution
    500 μL
    CEA089-B06
    Streptavidin-HRP Dilution Buffer
    15 mL
    CEA089-B07
    20×Washing Buffer
    50 mL
    CEA089-B08
    2×Sample Dilution Buffer
    15 mL×2
    CEA089-B09
    Substrate Solution
    12 mL
    CEA089-B10
    Stop Solution
    6 mL
  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data 

    Please refer to DS document for the assay protocol.

     ANGPTL3 TYPICAL DATA

    For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of ANGPTL3 is less than 0.156 ng/mL.

Validation
  • Sample Values

    Serum Sample: ANGPTL3 concentrations were measured in thirty-two human serum samples (sample dilution ratio 1:100), which were collected from healthy human subjects.

     ANGPTL3 SAMPLE VALUES
  • Dilution Linearity

    High concentrations of human ANGPTL3 serum samples were diluted with 1:2, 1:4, 1:8, 1:16 and 1:32 ratios for gradient dilution to evaluate the linearity of the assay. In the serum samples, the average detection rate of ANGPTL3 was 101.7%.

     ANGPTL3 DILUTION LINEARITY
  • Intra-Assay Statistics

    Ten replicates of each of four samples containing different ANGPTL3 concentrations were tested in one assay. Acceptable criteria: CV<10%.

     ANGPTL3 INTRA-ASSAY STATISTICS
  • Inter-Assay Statistics

    Five samples containing different concentrations of ANGPTL3 were tested in independent assays. Acceptable criteria: CV<15%.

     ANGPTL3 INTER-ASSAY STATISTICS
  • Recovery

    Recombinant ANGPTL3 was spiked into three human serum samples, and then analyzed. The average recovery of ANGPTL3 for serum samples is 100.5%.

     ANGPTL3 RECOVERY

Customer Reviews
Writing Reviews

Recent Advances

 
Contact Us
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews
Contact Us

전화
글로벌: +1 800-810-0816 (무료)
아시아태평양: +86 400-682-2521

주소 서울특별시 송파구 법원로11길 11, 제3층 제비-314,315호