Human ANGPTL3 ELISA Kit, PRO is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant human ANGPTL3 that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ELISA Kit provides several benefits:
- Standards to calibrate with NIBSC/WHO standards for comparable results.
- Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
- High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
- Simplified and straightforward protocols and ready-to-use reagents to save assay time.
Product Specifications
Assay TypeSandwich-ELISAAnalyteANGPTL3Format96-wells plate breakable into 12 x 8 wells stripsReactivityHumanSensitivity0.156 ng/mLAssay Time2.75 hrSample volume50 μLRange0.156 ng/mL-10 ng/mLSample TypeCell Culture Supernatants, Plasma, Serum.Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.
Application
The kit is developed for quantitative detection of natural and recombinant human ANGPTL3 in serum, plasma and cell culture supernatants.
It is for research use only.
Workflow

Storage
Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
Materials Provided
IDComponentsSizeCEA089-B01Pre-coated Anti-ANGPTL3 Antibody Microplate1 plateCEA089-B02Human ANGPTL3 Standard40 μg×2CEA089-B03Biotin-Anti-ANGPTL3 Antibody Con. Solution100 μLCEA089-B04Biotin-Antibody Dilution Buffer8 mLCEA089-B05Streptavidin-HRP Con. Solution500 μLCEA089-B06Streptavidin-HRP Dilution Buffer15 mLCEA089-B0720×Washing Buffer50 mLCEA089-B082×Sample Dilution Buffer15 mL×2CEA089-B09Substrate Solution12 mLCEA089-B10Stop Solution6 mLACRO Quality Management System
Customers Also Viewed
Performance Data
Typical Data
Please refer to DS document for the assay protocol.

For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of ANGPTL3 is less than 0.156 ng/mL.
Sample Values
Serum Sample: ANGPTL3 concentrations were measured in thirty-two human serum samples (sample dilution ratio 1:100), which were collected from healthy human subjects.

Dilution Linearity
High concentrations of human ANGPTL3 serum samples were diluted with 1:2, 1:4, 1:8, 1:16 and 1:32 ratios for gradient dilution to evaluate the linearity of the assay. In the serum samples, the average detection rate of ANGPTL3 was 101.7%.

Intra-Assay Statistics
Ten replicates of each of four samples containing different ANGPTL3 concentrations were tested in one assay. Acceptable criteria: CV<10%.

Inter-Assay Statistics
Five samples containing different concentrations of ANGPTL3 were tested in independent assays. Acceptable criteria: CV<15%.

Recovery
Recombinant ANGPTL3 was spiked into three human serum samples, and then analyzed. The average recovery of ANGPTL3 for serum samples is 100.5%.